"SBA-5" high expansion display of Yingchi Technology

â– SBA-5 series introduction:

PP Systems is a world-renowned company specializing in the development and development of plant physiology and ecological science instruments and high quality infrared CO2/H2O analyzers. Dr. Keith J Parkinson, the founder of the company, has more than 30 years of experience in producing high quality infrared CO2/H2O analyzers. He designed the world's first open gas path photosynthetic system, which is widely used in many international photosynthetic systems. Adopted, the core high-quality infrared CO2/H2O analyzer provides open source development ports for the majority of companies. After the founding of PP Systems in 1984, the company has a number of patented technologies such as auto-zeroing and differential balancing of the world's unique infrared analyzers to produce a world of high-quality infrared CO2/H2O analyzers.

The two technologies of automatic zero adjustment and differential balance ensure data accuracy and avoid human error. In the measurement, once the instrument detects that the difference exceeds the specification, it will automatically zero and balance immediately, without human intervention, and ensure data consistency.

At present, the company has CIRAS series ultra-high precision CO2/H2O analyzer, EGM series portable high-precision CO2/H2O analyzer, WMA series laboratory high-precision CO2/H2O analyzer, SBA series high-precision open source CO2/H2O analyzer.

Measurement parameters (function): Accurate measurement of CO2 concentration, temperature, humidity, oxygen, etc. in the environment or container

Main applications: environmental gas monitoring, indoor environmental control, atmospheric research, growth chamber, biodegradation, CO2 storage and escape, animal and plant respiration, fruit and vegetable storage, brewery, medical equipment, CO2 leakage, indoor air quality and safety, industrial monitoring, Oceanography and other research

â–  SBA-5 performance:

â—‹ Measurement method: Microcomputer controlled linear non-dispersive infrared gas absorption meter

â—‹CO2 measurement range: 0-1000ppm (accuracy 0.1%)

â—‹ Pressure compensation range: 80-115kPa

â—‹ Accuracy: 0.1% within the calibration range, the actual accuracy is affected by the accuracy of the calibration gas

â—‹ Linearity: <1% within the range

â—‹ Accuracy: It can automatically zero at specified intervals to correct drift caused by sample chamber contamination, light source and detector aging, preamplifier gain change

â—‹ Analyzer gas flow rate: can be selected in the range of 100-1000 cc / min. Recommended flow rate 200-500cc/min

â—‹ Correction: User-programmable calibration (if needed)

â—‹ Analog signal output: dual 0-5V linear output (CO2 and H2O); 4-20mA (CO2 only)

â—‹ Digital interface: RS-232 (interface); USB (Mini interface); humidity probe input

â—‹ Power supply mode: 6-18V DC

â—‹ Power consumption: about 9W in the warm-up phase; 1-3W in the normal operation phase

○ Operating temperature range: -20 ° C to +50 ° C

â– SBA-5 advantages:

â—‹ Strong compatibility: SBA-5 is very suitable for OEM users, and can be used as accessories for various large-scale equipment as needed.

â—‹ Lightweight: The board only weighs 200g, including the original outer casing 400g, which greatly reduces the difficulty of installation.

○ small: board size 7.5cm × 12cm × 3.5cm; including the outer casing 8cm × 13cm × 4.5cm;

â—‹ Strong scalability: SBA-5 provides a variety of input and output interfaces, and can be flexibly matched with a variety of external probes, indicating instruments, data collectors, etc.

â—‹ Convenient data transmission: Provide mini USB and RS-232 interface for users to carry out PC-SBA-5 data connection, convenient to transfer data

â—‹ Low power consumption: the power consumption is only 1-3 watts during normal use, and the user has strong battery life when using non-communication power such as batteries in the field.

â—‹ open source design, users can self-program,

â—‹ Standard transmission protocol: 0-5V linear output (CO2 & H2O), 4-20mA (CO2)

â–  SBA-5 indicator:

â—‹CO2 measuring probe: IRGA gas analyzer with a range of 0-1000ppm and an accuracy of 0.1% within the calibration range

â—‹O2 probe: OP2 oxygen probe, the range of 0-30%, the accuracy is 1% of the calibration range

â—‹ Humidity probe: non-condensing type, measuring range 0-95%, accuracy 2% (no correction required)